ISI Papers With Our Products
Title: A continuous flow microfluidic device based on contactless dielectrophoresis for
bioparticles enrichment
Journal: Electrophoresis
Author: 1. Ali Rahmani, Aliasghar Mohammadi, 2. Hamid Reza Kalhor
Year: 2018
Address: 1. Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
2. Biochemistry Research Laboratory, Department of Chemistry, Sharif University of Technology, Tehran, Iran
Abstract: In recent years, applications of dielectrophoresis-based platforms have been recognized as effective and dependable approach to separate cells and bioparticles, suspended in different
carrier fluids, based on particle size and electrical properties. In this study, a microfluidic
device was fabricated by an unprecedented electrode pattern, and several experiments were
performed to enrich samples including either of yeast, Escherichia coli, or latex particles.
A chemical deposition-based method was employed for fabrication of microelectrodes,
inducing nonuniform electric field required for dielectrophoresis-based separation. One
major advantage of our employed method is low fabrication cost, in addition to its accuracy
and operation at low voltages. The performance of the microfluidic device in enriching
either of injected samples was studied using spectrophotometric techniques. The effects
of experimentally controllable parameters (applied-voltage amplitude and frequency, and
flow rate) were studied by changing a parameter while keeping the others constant. It
became evident that all the aforementioned parameters had modulating impact on the
performance of the microfluidic device. Furthermore, to investigate binary interactions
among the parameters, response surface methodology was exploited, resulting in a secondorder
polynomialmodel for the performance of the device as a function of the parameters.
The model was employed for finding the optimum values of the parameters at which
the performance of the device is the highest. At optimum values for the experimentally
controllable parameters, enrichment efficiencies of 87 ± 2, 82 ± 4, and 86 ± 3% for,
respectively, yeast, E. coli, and latex particles were obtained experimentally, confirming the
ability of the proposed method for biological and polymeric particles enrichment.
Keywords: Bioparticle enrichment, Dielectrophoresis, E. coli / Microfluidics, Yeast
Application: Microfluidic Device
Product Model 1: Syringe Pump (HSP 2000)
Product Model 2:
URL: #http://onlinelibrary.wiley.com/doi/10.1002/elps.201700166/full#